ABB DO802 3BSE022364R1 | S800 | Digital Output Relay 8 ch

ABB DO802 3BSE022364R1 | S800 | Digital Output Relay 8 ch

Brand: ABB

Product ID: DO802 3BSE022364R1

Condition: New / used

Terms of payment: Paypal、T/T 、Western Union

Category:

Description

ABB DO802 3BSE022364R1

I. Overview


ABB DO802 3BSE022364R1 is a digital output module, whose core positioning is a basic digital signal output terminal connecting industrial automation control systems and field execution devices. Designed specifically for simple control signal transmission scenarios, it can accurately receive the logic operation results of the AC 800M controller and stably output digital control signals to field execution devices (such as relays, contactors, solenoid valves, indicator lights, etc.). It realizes basic control functions including equipment start-stop control, status switching and interlock action triggering, providing reliable signal output support for basic execution control, simple equipment linkage and production status switching in industrial processes. This module is widely applicable to industrial scenarios that require simple signal output functions and pursue high reliability and cost-effectiveness, such as general manufacturing, municipal engineering, small-scale water treatment equipment and light processing production lines. It is especially suitable for control systems with small demand for output channels and simple system architecture.


Adopting an industrial-grade high-reliability compact design, the module optimizes the structural layout on the premise of ensuring the stability of core output functions. It has excellent anti-interference capability and wide environmental adaptability, and can operate stably for a long time in harsh industrial environments with high temperature, vibration and strong electromagnetic interference. Relying on ABB's profound technical accumulation in the field of industrial automation, the DO802 3BSE022364R1 supports seamless connection with AC 800M series controllers and other I/O modules, and has basic expansion capability and convenient configuration functions. Meanwhile, it is built with a practical online diagnosis mechanism, which can quickly locate common fault points, reduce operation and maintenance costs, and meet the needs of building new small-scale industrial automation systems, upgrading old and simple systems, and expanding capacity for basic signal output scenarios.



II. Product Features


  • Basic Channel Configuration: Adopting a compact channel integrated design, it is equipped with 8 independent digital output channels with a compact and reasonable layout, which accurately matches the needs of simple signal output scenarios. While ensuring output stability, it saves cabinet installation space to the greatest extent and reduces system construction and operation and maintenance costs, making it an ideal basic output component for small-scale industrial control systems.


  • High-Reliability Industrial-Grade Architecture: Selected high-quality industrial-grade core components and reinforced compact circuit design, it has passed strict electromagnetic compatibility (EMC) certification, environmental reliability testing and industry safety certification. It can operate stably in harsh industrial environments with a long mean time between failures (MTBF), providing a solid guarantee for the continuity and safety of small-scale industrial production.


  • Accurate and Stable Basic Output Capability: The 8 output channels are fully electrically isolated with an isolation voltage of ≥500V AC, effectively avoiding signal interference between channels. It supports 24V DC signal output mode and is compatible with PNP/NPN drive types, which can accurately drive various basic digital execution devices on site. The output response time is flexibly configurable (minimum ≤1ms), which can quickly respond to controller commands and meet the needs of basic high-speed response control scenarios.


  • Flexible System Adaptation and Expansion Capability: Designed specifically for ABB AC 800M series control systems, it can achieve high-speed data interaction with controllers through communication interface modules such as CI854. It supports cascade expansion of up to 32 same-series I/O modules, with a maximum expandable I/O point count of 256, adapting to the expansion needs of small and medium-sized industrial control systems. It is compatible with ABB Control Builder M configuration software, facilitating parameter configuration, program debugging and running status monitoring.


  • Practical Online Diagnosis Function: Built-in complete basic self-diagnosis and fault monitoring mechanism, it real-timely monitors the module power supply status, output status of each channel, bus communication status and connection status of external execution devices. It can accurately locate common fault channels and fault types (such as line short circuit, output overload, channel open circuit, execution device fault, etc.), and upload fault information to the controller and upper computer system via the bus, facilitating quick handling by operation and maintenance personnel and shortening fault troubleshooting time.


  • Strong Environmental Adaptability and Anti-Interference Capability: The operating temperature range covers -25℃~+60℃, enabling stable operation in wide-temperature environments. It has excellent vibration resistance (2g, 10Hz~150Hz) and shock resistance (10g, 11ms) performance. Adopting reinforced electromagnetic shielding design and built-in signal filtering circuit, it can effectively resist electromagnetic interference and surge interference generated by high-power equipment in industrial sites, ensuring the stability and accuracy of basic signal output.


  • Convenient Operation and Maintenance and Management Design: Supporting module-level online hot swap function, it can complete module installation, replacement and maintenance without interrupting system operation, greatly reducing production losses caused by small-scale system downtime. Equipped with intuitive local status indicators (power supply, operation, communication, channel group status), operation and maintenance personnel can quickly judge the overall operation status of the module and channel group fault conditions through the indicators, and accurately locate single-channel faults combined with the upper computer, improving operation and maintenance efficiency.


  • Comprehensive Output Protection Function: Each output channel is equipped with overcurrent protection, short-circuit protection and reverse polarity protection circuits. When detecting excessive output current (maximum withstand current ≤2A per channel, subject to the official manual), line short circuit or reverse connection of power supply positive and negative poles, it can quickly cut off the output loop to avoid damage to the module and field execution devices. After the fault is eliminated, the module can automatically restore normal output function without manual reset, reducing the difficulty of operation and maintenance.



III. Technical Parameters


1. Core Basic Parameters

  • Product Model: ABB DO802 3BSE022364R1
  • Product Type: Basic digital output module
  • Manufacturer: ABB Group
  • Product Series: I/O component of AC 800M series control system
  • Core Functions: Receive controller commands, output on-site basic digital signals, monitor channel status, online fault diagnosis
  • Communication Method: Communicate with the controller via PROFIBUS DP bus (matching corresponding communication interface module is required)
  • Applicable System: ABB AC 800M series industrial automation control system
  • Application Fields: General manufacturing, municipal engineering (such as street lamp control, small pumping station), small-scale water treatment equipment, light processing production line, warehousing and logistics auxiliary equipment, pharmaceutical auxiliary equipment, food processing auxiliary production line, etc.


2. Electrical Performance Parameters

  • Supply Voltage: 24V DC (voltage fluctuation range: 20.4V DC ~ 28.8V DC)
  • Output Type: Digital output (PNP/NPN compatible, source/sink output selectable)
  • Channel Quantity: 8 independent digital output channels (fully isolated between channels, isolation voltage ≥500V AC)
  • Output Voltage Range: 24V DC (rated output)
  • Output Current: Maximum output current per channel ≤2A (subject to the official manual), total output current ≤8A (module overall)
  • Output Response Time: Configurable, minimum ≤1ms, maximum ≤100ms
  • Output Protection: Overcurrent protection, short-circuit protection, reverse polarity protection
  • Fault Diagnosis Range: Channel short circuit, output overload, power supply abnormality, communication interruption, channel open circuit, execution device fault
  • Communication Interface: Connect with communication interface module (such as CI854) via I/O bus
  • Communication Protocol: Support PROFIBUS DP V1/V2 protocol
  • I/O Expansion Capability: Support cascade connection of up to 32 same-series I/O modules, maximum expandable I/O point count of 256
  • Driven Device Type: Field relays, contactors, solenoid valves, indicator lights, small pumps, fans and other basic digital execution devices


3. Environmental and Physical Parameters

  • Operating Temperature: -25℃~+60℃
  • Storage Temperature: -40℃~+85℃
  • Relative Humidity: 5%~95% RH (no condensation)
  • Vibration Resistance: 2g, 10Hz~150Hz (sine wave)
  • Shock Resistance: 10g, 11ms (half-sine wave)
  • Protection Grade: IP20 (module itself); IP54 (when installed in standard cabinet)
  • Weight: Approximately 0.6kg (module itself); 2.0kg (including transportation package)
  • Installation Method: Rack-mounted installation (adapt to ABB standard I/O cabinet, comply with IEC 60917 standard)
  • Dimensions (Length × Width × Height): 140mm × 100mm × 55mm
  • Special Functions: Online hot swap, independent channel isolation, online fault diagnosis, output overcurrent protection


IV. Working Principle


The core working principle of ABB DO802 3BSE022364R1 is a closed-loop workflow of command receiving - signal processing - output driving - status monitoring - fault feedback. Through the coordinated operation of the communication receiving unit, signal processing unit, output driving unit and fault diagnosis unit inside the module, it realizes accurate reception of controller commands and reliable driving of field execution devices. The specific working process can be divided into four core stages:


Stage 1: System Initialization and Parameter Configuration StageAfter the module establishes a connection with the communication interface module (such as CI854) of the ABB AC 800M controller via the I/O bus and is connected to the 24V DC power supply, it automatically completes initialization and startup, performs internal circuit self-test, calibrates 8 channels one by one and verifies the communication link. Operation and maintenance personnel complete the basic configuration of output response time, fault diagnosis threshold (such as overcurrent threshold), output type (PNP/NPN), communication parameters, etc. through the ABB Control Builder M configuration software, ensuring that the module is accurately adapted to the controller and field execution devices, and meets the response requirements of simple signal output.


Stage 2: Controller Command Receiving and Processing StageAccording to the logic operation results, the AC 800M controller transmits digital control commands (such as equipment start-stop and status switching commands) to the communication interface module via the PROFIBUS DP bus. The communication interface module converts the commands into a format recognizable by the I/O bus and transmits them to the communication receiving unit of the DO802 module. The signal processing unit inside the module parses and verifies the commands, filters invalid commands and interference signals, and generates standardized output driving signals to ensure the accuracy and reliability of command transmission.


Stage 3: Output Driving and Equipment Control StageThe standardized output driving signals are transmitted to the 8 independent output channels of the module, amplified by the driving circuit built into the channels, and then output to the corresponding field execution devices. According to the configured output type (PNP/NPN), the module accurately provides driving current/voltage to trigger the execution devices to complete corresponding actions (such as relay pull-in, solenoid valve opening, indicator light on, etc.). Meanwhile, the module real-timely collects the output status signals of each channel to provide data support for subsequent status monitoring.


Stage 4: Full Status Monitoring and Fault Diagnosis StageThe fault diagnosis unit real-timely monitors the module power supply status, independent status (output voltage and current) of 8 output channels, bus communication status and connection status of external execution devices. If detecting problems such as short circuit of a certain channel, output overload, execution device fault, communication interruption or power supply fault, it immediately activates the corresponding protection mechanism (such as cutting off the output of the faulty channel without affecting the normal operation of other channels). Meanwhile, it generates detailed fault codes including the faulty channel number and fault type, and uploads the fault information to the controller and upper computer system via the bus. After receiving the fault information, the controller prompts the module or channel group fault status through local indicators, and the upper computer system accurately displays the details of the faulty channel, reminding operation and maintenance personnel to handle it quickly and reducing the operation and maintenance difficulty of small-scale systems.



V. Common Fault Troubleshooting


1. No Signal Output/Output Abnormality in Partial/All Output Channels

Phenomenon: After the controller issues control commands, partial or all output channels of the DO802 module have no signal output; the output signals cannot drive the field execution devices to act; the actions of the execution devices are inconsistent with the controller commands; the status indicator of the corresponding channel group of the module is abnormal (not lit or always on).
Causes: Unstable module supply voltage or exceeding the standard range of 20.4V DC ~ 28.8V DC; loose, poor contact, damaged or short-circuited lines between partial or all output channels and execution devices; fault of field execution devices (such as damaged relay coils, stuck solenoid valves, burned indicator lights); fault of partial or all module output channels (damaged driving circuits); interrupted connection link between the module and communication interface module; incorrect parameter configuration of output channels (such as mismatched output type, too long response time setting); signal distortion caused by strong field electromagnetic interference.
Solutions: 1. Use a multimeter to detect the module supply voltage to ensure it is stable within the standard range. If the voltage fluctuates greatly, replace it with a high-precision regulated power supply module. 2. Cut off the power supply, check the connection status of the lines between the output channels and the execution devices, tighten loose joints, and repair or replace damaged or short-circuited lines. 3. Check the working status of the field execution devices, use professional tools to detect whether the drive end of the devices can normally receive signals, troubleshoot equipment faults, and replace faulty equipment in a timely manner. 4. Switch the execution device of the faulty channel to the backup channel for testing. If the backup channel output is normal, determine that the original channel is faulty; if multiple channels fail at the same time, it is necessary to troubleshoot the overall module fault. 5. Check the connection link between the module and the communication interface module, tighten the bus joints to ensure normal communication. 6. Verify the output channel parameter configuration through the Control Builder M software, adjust parameters such as output type and response time, and test after reconfiguration. 7. Keep the output lines away from strong electromagnetic interference sources such as frequency converters and high-power motors, preferentially use shielded cables and ground them reliably (grounding resistance ≤4Ω) to enhance anti-interference capability.


2. Frequent Fault Alarms/False Alarms of Output Channels

Phenomenon: The module frequently prompts fault alarms of single or multiple output channels; channels falsely report faults when no controller command is issued; the controller displays channel fault codes (such as overcurrent and short-circuit faults), and the module fault indicator is always on or flashes frequently.
Causes: Overload of field execution devices (load current exceeds the maximum output current of the channel); short circuit, leakage or poor contact of partial output lines; fault of the internal driving circuit or isolation circuit of partial output channels of the module; too low fault diagnosis threshold setting (such as too small overcurrent threshold setting); abnormal operation caused by poor module heat dissipation; condensation and oxidation of channel terminals caused by humid field environment, reducing insulation performance.
Solutions: 1. Verify the load current of the field execution device corresponding to the faulty channel to ensure it does not exceed the maximum output current of the channel. If the load is abnormal, troubleshoot problems such as equipment jamming and overload, or replace the execution device suitable for the load. 2. Cut off the power supply, check the insulation status of the output lines corresponding to the faulty channel, troubleshoot line short circuit and leakage problems, and repair abnormal lines. 3. Switch the execution device of the faulty channel to the backup channel for testing. If the fault disappears, determine that the internal circuit of the original channel is faulty, and the faulty module needs to be replaced through hot swap. 4. Verify the fault diagnosis threshold setting through the configuration software, and adjust it to a reasonable range according to the actual load of the field execution device. 5. Check the heat dissipation of the module installation environment, clean the dust on the module surface, ensure sufficient heat dissipation space around (at least 10cm on both sides is recommended) to avoid abnormal module operation caused by high temperature. 6. In humid environments, strengthen the moisture-proof protection of the module, check whether there is condensation and oxidation on the channel terminals, clean the oxide layer and take good moisture-proof measures.


3. Abnormal Communication Between Module and Controller

Phenomenon: The module cannot establish communication with the ABB AC 800M controller; the controller cannot identify the DO802 module; controller commands cannot be issued or are frequently interrupted during issuance; the module communication status indicator flashes abnormally.
Causes: Loose, poor contact or damaged bus connection between the module and the communication interface module (such as CI854); incorrect communication parameter configuration (such as address conflict, mismatched protocol version, mismatched data transmission rate); fault of the communication interface module; fault of the internal communication unit of the module; the module fails to complete initialization or initialization fails.
Solutions: 1. Cut off the power supply, check the bus connection status between the module and the communication interface module, re-plug and tighten the joints, clean impurities at the joints, and repair or replace damaged buses. 2. Verify the communication parameter configuration through the Control Builder M software, ensure the module address is unique without conflict, the protocol version matches the controller, and the data transmission rate is adapted, and restart the system after reconfiguration. 3. Replace the backup communication interface module for testing. If the communication returns to normal, determine that the original communication interface module is faulty and needs to be replaced in a timely manner. 4. Replace the backup DO802 module for testing. If the communication returns to normal, determine that the internal communication unit of the original module is faulty, and it is necessary to contact ABB official after-sales service for maintenance. 5. Check the module initialization status. If initialization fails, restart the module or re-initialize through the configuration software.


4. Module Fails to Start/Power Indicator Has No Response

Phenomenon: After connecting to the 24V DC power supply, the module power indicator has no response and cannot start; the controller cannot detect the module; the module has no feedback to configuration commands.
Causes: Fault of the power supply or poor contact of the power interface; reverse connection of power supply positive and negative poles; short circuit of the internal power supply circuit of the module or component aging; poor connection between the module and the rack leading to abnormal power supply; module hardware damage.
Solutions: 1. Check whether the power supply outputs normally, replace it with a backup power supply for testing; re-plug the power interface, tighten the joint, verify the power supply positive and negative wiring, and correct wrong wiring. 2. Check the connection status between the module and the rack, tighten the mounting screws to ensure good contact and avoid abnormal power supply caused by poor contact. 3. After cutting off the power supply, wait for 5 minutes, reconnect the power supply to try to start, eliminating the startup fault caused by instantaneous voltage impact. 4. If it still cannot start or has no response, the internal hardware of the module may be damaged, and it is necessary to contact ABB official after-sales service for testing and maintenance.

contact us