Description
ABB REF620E_F NBFNAAAANDA1BNN1XF
1. Basic Information
ABB REF620E_F NBFNAAAANDA1BNN1XF is a high-end digital feeder protection and control IED, compliant with IEC international power standards. Integrating protection, measurement, control, fault recording and remote communication functions, it is applicable to radial, loop and meshed medium-voltage distribution networks, as well as distributed power grid-connected systems. Featuring high-speed sampling, millisecond-level protection response, multi-group parameter switching and advanced fault diagnosis, it is widely used in industrial plants, substations and municipal power distribution systems as a core intelligent power distribution device.
2. Technical Specifications
2.1 Basic Parameters
- Model: REF620E_F NBFNAAAANDA1BNN1XF
- Device Type: Medium Voltage Feeder Protection & Control IED
- Structure: 4U Rack Mount, Plug-in Modular Design
- Weight: 8.0kg
- Protection Class: Front IP54, Rear IP20
2.2 Sampling & Accuracy
- Sampling Rate: 2000 samples/s
- Measurement Class: 0.2S High Precision
- Protection Response: <1ms Ultra-fast action
- Setting Groups: 6 independent switchable parameter groups
2.3 I/O Configuration
- Digital Input: 16-channel DI
- Relay Output: 8-channel DO
- Analog Acquisition: 3-phase current & voltage synchronous sampling
- Terminal Type: Ring ear stable wiring terminals
2.4 Communication Parameters
- Ethernet Port: Dual redundant industrial Ethernet ports
- Serial Port: 1×RS485
- Protocol Support: IEC61850, Modbus TCP, Modbus RTU
- Function: Remote control, parameter setting, data upload, wave recording retrieval
2.5 Electrical & Environmental Parameters
- Power Supply: 80~250V AC/DC Wide-range universal power
- Operating Temperature: -25℃~+70℃
- Storage Temperature: -40℃~+85℃
- Humidity: 5%~95%RH (Non-condensing)
- Feature: High EMC anti-interference, vibration resistance, anti-aging
3. Main Features
- Full-range Feeder Protection: Integrates overcurrent, earth fault, over/under voltage, overload, frequency protection, as well as advanced HIZ, CFD and AFD arc fault detection functions to cover all common feeder faults.
- Ultra-fast Millisecond-level Protection: <1ms rapid tripping response effectively isolates short circuit, grounding and arc faults to minimize grid impact and equipment damage.
- High-precision Power Measurement: 0.2S-level accuracy realizes full electrical parameter measurement, power statistics and power quality analysis for medium-voltage feeders.
- Multi-working-condition Adaptive Switching: 6 independent setting groups support flexible parameter switching to adapt to grid load changes and diversified operation modes.
- Complete Fault Recording & Event Logging: High-frequency transient wave recording and full-time event recording support accurate fault tracing and system operation analysis.
- Dual Redundant Stable Communication: Dual Ethernet redundant architecture ensures uninterrupted data transmission and stable remote monitoring of digital substations.
- Plug-and-maintain Modular Design: Removable modular structure enables fast replacement and convenient maintenance, adapting to unattended substation operation scenarios.
- Harsh Environment Adaptability: High-standard EMC design ensures stable long-term operation under strong electromagnetic interference and wide temperature fluctuation conditions.
4. Working Principle
- Power-on Self-check Initialization: Complete hardware self-inspection, program loading and communication initialization after power-on, and enter normal monitoring state.
- High-speed Signal Sampling: Synchronously collect three-phase voltage, current and switch state signals at 2000Hz, with filtering and anti-interference processing.
- Real-time Logic Judgment: Compare real-time sampling data with preset protection values to monitor various fault characteristics and operating conditions.
- Fast Protection Action Output: Trigger tripping and alarm instructions within milliseconds when faults occur to isolate faulty circuits and prevent fault expansion.
- Fault Data Recording: Automatically record transient waveforms, event sequences and action logs to retain complete fault analysis data.
- Remote Data Interaction: Upload operating data and receive remote control commands through redundant communication ports to realize intelligent remote operation and maintenance.
5. Applications
5.1 Industrial Medium-voltage Distribution Room
Used for protection and monitoring of industrial 10kV/35kV feeder circuits to ensure stable operation of industrial power distribution systems.
5.2 Municipal Substation Distribution System
Adapt to ring network and mesh network operation modes, realizing fast fault isolation and self-healing to improve power supply reliability.
5.3 New Energy Grid-connected System
Stable protection and monitoring for photovoltaic and wind power grid-connected feeders, adapting to fluctuating new energy operating conditions.
5.4 Digital Substation Renovation
Fully compatible with IEC61850 standard, supporting intelligent interconnection and unified management of digital substations.
5.5 Old Equipment Maintenance & Replacement
Replace outdated traditional protection devices to upgrade distribution system protection accuracy and intelligent operation level.